Through a macro inspection, chemical composition analysis, hardness inspection, graphite carbon inspection and energy spectrum analysis, the reason for the
The Ohio State University (OSU) team will develop a MVDC circuit breaker prototype based on its novel "T-breaker" topology. OSU will leverage its unique high voltage and real-time simulation facilities, circuit prototyping experience with MV silicon carbide devices, and capability in developing protection strategies for faults in DC
Aiming at the problem of energy storage unit failure in the spring operating mechanism of low voltage circuit breakers (LVCBs). A fault diagnosis algorithm based on an improved
Abstract: Energy storage spring is an important component of the circuit breaker''s spring operating mechanism. A three-dimensional model of the opening spring and closing spring of the 126kV circuit breaker was established through COMSOL, and the stress and
As a powerful component of a circuit breaker, the reliability of energy storage spring plays an important role in the drive and control the operation of a circuit breaker motion process.
Select the evaluation characteristic quantity of performance state, calculate the energy storage spring impulse according to the momentum theorem, and obtain the
accuracy of circuit breaker energy storage mechanism. Compared with the traditional method, the proposed method has ob vious Pow er automation equipment, Vol. 3 3, Issue 2, 2013, p. 115-119
One of the most causing closing fault of high voltage circuit breaker is closing spring failure. In order to avoid such closing fault, this paper analyzed the relationship between energy of closing spring and its load, as well as the experiment carried out to get the minimum energy when closing. The time-varying static stress
The force of closing spring under the minimum energy required f or closing of high-voltage circuit. breaker is the minimum force allo wed. When the force of closing spring f=2656.2N (energy of
The phenomenon that the reliability of energy storage spring decreases with the increase of operation times is studied Combined with the energy storage spring model of 126KV
Bringing Zero closer: high-voltage circuit breakers. Our Blue circuit breakers with Zero F-gases and Zero harm make greener grids up to 145 kV achievable. Also for higher voltages up to 1100 kV we offer reliable live tank and dead tank circuit breakers as well as hybrid solutions combining different functions in a compact design, such as our
The energy storage state of the closing spring in the spring operating mechanism affects the closing characteristics of the high-voltage circuit breaker. The
The performance state evaluation method of circuit breaker energy storage spring mainly judges its performance state indirectly by measuring the pre-tightening force or pre-pressure of the spring. However, there may be some errors in this indirect measurement method, which will affect the accuracy of the evaluation results. Therefore, the performance state
The performance state evaluation method of circuit breaker energy storage spring mainly judges its performance state indirectly by measuring the pre
The performance state evaluation method of circuit breaker energy storage spring mainly judges its performance state indirectly by measuring the pre-tightening force or pre-pressure of the spring. However, there may be some errors in this indirect measurement method, which will affect the accuracy of the evaluation results.
A fault identification method for circuit breaker energy storage mechanism, combined with the current–vibration signal entropy weight characteristic and grey wolf optimization-support vector machine (GWO-SVM), is proposed by analyzing the energy conversion and transmission relationship between control loop, motor,
The vibration signal of the circuit breaker during closing and closing contains its state characteristic information, the vibration signals of different faults will have certain differences.
A fault identification method for circuit breaker energy storage mechanism, combined with the current-vibration signal entropy weight characteristic and
One of the most causing closing fault of high voltage circuit breaker is closing spring failure. In order to avoid such closing fault, this paper analyzed the
Energy storage spring is an important component of the circuit breaker''s spring operating mechanism. A three-dimensional model of the opening spring and closing spring of the 126kV circuit breaker was established through COMSOL, and the stress and strain distributions in the stored energy state and the non-stored energy state were obtained